IBM RS/6000 44P 270 Service Manual page 92

Rs/6000 44p series
Hide thumbs Also See for RS/6000 44P 270:
Table of Contents

Advertisement

Table 1. Service Processor Checkpoints. (continued)
Checkpoint
E080
E081
E0A0
E0B0
E0C0
E0D0
E0E0
74
Service Guide
Description
Entering service processor
emergency firmware flash recovery
process.
Flash update completed - system
reboot in progress.
Beginning bring-up phase
Starting processor BIST
Starting X5 BIST
Creating JTAG scanlog (failure
diagnostic information).
Beginning to pull processor card out
of reset state.
Action/ Possible Failing FRU
1. Insert a brand new,
DOS-formatted diskette
containing the service processor
firmware into the diskette drive.
The firmware image file name
must be 'spflash.img'.
Note: Insert the diskette only
after E080 shows on the operator
panel.
2. Cycle ac power and return the
flash recovery.
3. Cycle ac power, get another
*brand new* floppy disk and retry
the flash recovery.
4. Replace I/O board.
1. Cycle ac power and attempt a
reboot.
2. Retry a service processor
emergency flash update (if
possible) as documented in
checkpoint code E080.
3. Replace I/O board. (See notes on
page 93.)
1. Replace processor card(s).
2. Replace I/O board. (See notes on
page 93.)
1. Consult the service processor
error logs for potential failing
FRUs.
2. Replace processor card.
3. Replace I/O board. (See notes on
page 93.)
1. Replace processor card.
2. Replace I/O board. (See notes on
page 93.)
1. Replace processor card(s).
2. Replace I/O board. (See note on
page 93.)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7044-270

Table of Contents