IBM RS/6000 44P 270 Service Manual page 105

Rs/6000 44p series
Hide thumbs Also See for RS/6000 44P 270:
Table of Contents

Advertisement

Table 2. Firmware Checkpoints. (continued)
Checkpoint
Description
E207
Setup data gather mode and 64/32-bit
mode on PCG.
E208
Assign bus number on PCG.
E209
Assign PCI I/O addresses on PCI.
E20A
Assign PCI I/O addresses on PCG
E20B
Check MCERs stuck at fault.
E20C
Testing L2 cache.
E210
Processors L1 data cache array test
fails. System hangs.
E211
IPL ROS CRC checking.
E212
Processor POST.
E213
Initial memory configuration.
E214, E218
Memory test.
E216
Copy ROS into RAM. Setup translation
and C environment.
Action/ Possible Failing FRU
1. Replace the I/O board (See note on
page 93.)
2. Go to "MAP 1540: Minimum
Configuration" on page 50.
1. Replace the I/O board (See note on
page 93.)
2. Go to "MAP 1540: Minimum
Configuration" on page 50.
1. Replace the I/O board (See note on
page 93.)
2. Go to "MAP 1540: Minimum
Configuration" on page 50.
1. Replace the I/O board. (See note on
page 93.)
2. Go to "MAP 1540: Minimum
Configuration" on page 50.
1. Replace the system board.
2. If the problem persists, go to "MAP
1540: Minimum Configuration" on
page 50.
1. Replace the processor card.
2. Go to "MAP 1540: Minimum
Configuration" on page 50.
1. Replace I/O board.
2. Go to "MAP 1540: Minimum
Configuration" on page 50.
1. Replace the I/O board. (See note on
page 93.)
2. Go to "MAP 1540: Minimum
Configuration" on page 50.
1. Replace the processor card.
2. Go to "MAP 1540: Minimum
Configuration" on page 50.
Go to "MAP 1240: Memory Problem
Resolution" on page 39.
Go to "MAP 1240: Memory Problem
Resolution" on page 39.
1. Replace the memory card .
2. Go to "MAP 1540: Minimum
Configuration" on page 50.
Chapter 4. Checkpoints