Purpose of this MAP
This MAP is used to locate defective FRUs not found by normal diagnostics. For this
procedure, diagnostics are run on a minimally configured system. If a failure is detected
on the minimally configured system, the remaining FRUs are exchanged one at a time
until the failing FRU is identified. If a failure is not detected, FRUs are added back until
the failure occurs. The failure is then isolated to the failing FRU.
Step 1540-1
1. Insert the diagnostic CD-ROM into the CD-ROM drive.
Note: If you cannot insert the diagnostic CD-ROM, go to "Step 1540-2" on page 52.
2. Ensure that the diagnostics and the operating system are shut down.
3. Turn off the power.
4. Turn on the power.
5. When the keyboard indicator is displayed (the word keyboard on an ASCII terminal
or the keyboard icon on a graphical display), press the F5 key on the directly
attached keyboard or the number 5 key on an ASCII terminal.
6. Enter the appropriate password if you are prompted to do so.
Is the "Please define the System Console" screen displayed?
NO
YES
Go to "Step 1540-2" on page 52.
Go to "Step 1540-18" on page 66.
Chapter 3. Maintenance Analysis Procedures
51