Step 1240-8; Step 1240-9 - IBM RS/6000 44P 270 Service Manual

Rs/6000 44p series
Hide thumbs Also See for RS/6000 44P 270:
Table of Contents

Advertisement

Step 1240-8

1. Turn off the power.
2. Install one pair of memory modules.
3. Turn on the power.
Does the system stop with a memory checkpoint displayed on the operator
panel?
NO
YES

Step 1240-9

The failure may be caused by the last pair of memory modules installed or the memory
card. To isolate the failing FRU, do the following:
1. Turn off the power.
2. Exchange the last memory module pair installed.
3. Turn on the power.
Does the system stop with a memory checkpoint displayed on the operator
panel?
NO
YES
Repeat this step until all the memory modules are installed and tested.
If all the memory modules have been installed, reseating the memory modules
on the memory card has corrected the problem.
Go to "Map 0410: Repair Checkout" in the RS/6000 and Eserver pSeries
Diagnostics Information for Multiple Bus Systems.
Go to "Step 1240-9".
Go to "Step 1240-11" on page 44.
Go to "Step 1240-10" on page 44.
Chapter 3. Maintenance Analysis Procedures
43