Table 3. Firmware Error Codes. (continued)
Error Code Description
460000D8 A generic memory
controller-detected checkstop has
occurred.
460000D9 A generic I/O controller-detected,
checkstop has occurred.
Action / Possible Failing FRU
1. Try to reboot the system in service
mode to preserve the AIX error log.
Run diagnostics in problem
determination mode to determine
the cause of the failure if a new
SRN or error code is generated,
follow the actions for that code.
2. Try to boot AIX diagnostics from
CD-ROM.
v If the boot is successful, run
advanced diagnostics and follow
the actions for any SRN or error
code that is generated. If the
same error code is generated, go
to "MAP 1540: Minimum
Configuration" on page 50.
v If AIX standalone diagnostics do
not boot, follow the actions for
any new SRN or error code that
is generated. If the same error
code is generated, go to"MAP
1540: Minimum Configuration" on
page 50.
1. Try to reboot the system in service
mode to preserve the AIX error log.
Run diagnostics in problem
determination mode to determine
the cause of the failure if a new
SRN or error code is generated,
follow the actions for that code.
2. Try to boot AIX diagnostics from
CD-ROM.
v If the boot is successful, run
advanced diagnostics and follow
the actions for any SRN or error
code that is generated. If the
same error code is generated, go
to "MAP 1540: Minimum
Configuration" on page 50.
v If AIX standalone diagnostics do
not boot, follow the actions for
any new SRN or error code that
is generated. If the same error
code is generated, go to "MAP
1540: Minimum Configuration" on
page 50.
Chapter 5. Error Code to FRU Index
131