IBM RS/6000 44P 270 Service Manual page 135

Rs/6000 44p series
Hide thumbs Also See for RS/6000 44P 270:
Table of Contents

Advertisement

Table 3. Firmware Error Codes. (continued)
Error Code Description
40110008 Thermal failure detected in power
supply main enclosure.
40110009 Overcurrent on the main 5.0 V
was detected by the power
supply.
4011000A Overcurrent on the processor
card 5.0 V output was detected
by the power supply.
4011000B High 5.0 RA volt detected in
power supply main enclosure.
4011000C High 3.3 M volt detected in power
supply main enclosure.
4011000D Overcurrent on the 3.3 V output
was detected by the power
supply.
4011000E Overcurrent on the +12.0 V
output was detected by the power
supply.
4011000F Overcurrent on the -12.0 V output
was detected by the power
supply.
40110012 Voltage not found on I/O
expansion board.
40111002 Unknown power problem
detected.
40111022 A high 5.0 V reading detected.
Action / Possible Failing FRU
1. Check the connections between the
power supply connectors and to the
I/O board connectors.
2. Power supply
1. Check the connections between the
power supply connectors and to the
I/O board connectors.
2. Power supply
1. Possible processor card problem.
2. Go to "MAP 1520: Power "Step
1520-3" on page 46.
3. Processor card
4. Power supply
1. Check connector on the I/O board.
2. Replace power supply.
1. Check connector on the I/O board.
2. Replace power supply.
1. Check the connections between the
power supply connectors and to the
I/O board connectors.
2. Power supply
1. Check the connections between the
power supply connectors and to the
I/O board connectors.
2. Power supply
1. Check the connections between the
power supply connectors and to the
I/O board connectors.
2. Power supply
1. Check power interlock tab on I/O
expansion power FRU.
2. Check power cable at I/O expansion
board for proper seating.
3. Check interposer signal cable.
4. Check I/O expansion control cable.
5. Replace power supply.
6. Replace I/O expansion board.
7. Replace I/O expansion control
cable, I/O expansion power cable
and interposer signal cable
assemblies.
8. Replace interposer card.
Power supply.
1. Power supply.
2. Replace the I/O board. (See note on
page 93.
Chapter 5. Error Code to FRU Index
117

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7044-270