Table 3. Firmware Error Codes. (continued)
108
Service Guide
Error Code Description
28030002 Bad time/date values
28030003 RTC initialization required-RTC
not updating, not corrected.
28030004 RTC operating mode parameters
changed (such as data format)
28030005 RTC battery error
28030006 Processor frequency
measurement error
29000002 Keyboard/mouse controller failed
self-test.
29A00003 Keyboard not present/detected.
29A00004 Keyboard stuck key test failed.
29B00004 Mouse not present/detected.
2B2xxx11 Processor is manually disabled.
Action / Possible Failing FRU
1. Set the time and date.
2. Refer to Action under error code
28030xxx.
Replace I/O board. (See note on page
93.
1. Set/restore the time and date
2. Refer to RTC problem resolution
above if problem persists.
1. Replace the battery
2. Refer to RTC problem resolution
above if problem persists.
Password, time, and date must be
reset.
1. Verify that the current level of the
system firmware is installed.
2. Replace the processor card
3. Replace I/O planar
Replacing the battery does not
correct this error condition.
Replace the I/O board. (See note on
page 93.)
1. Keyboard
2. Replace the I/O board. (See note on
page 93.)
1. Keyboard
2. Replace the I/O board. (See note on
page 93.)
1. Mouse
2. Replace the I/O board. (See note on
page 93.)
Use service processor menus to
re-enable the processor and reboot the
system. See error code 2B2xxx22 for
xxx definitions.