Perform Engine Maintenance - Deutz 1011F Models; Drain The Fuel Filter/ Water Separator - Deutz Models - Genie GS-3390 Service Manual

Hide thumbs Also See for GS-3390:
Table of Contents

Advertisement

Section 3 • Scheduled Maintenance Procedures
CHECKLIST A PROCEDURES
A-10
Perform Engine Maintenance -
Deutz 1011F Models
Engine specifications require that this procedure
be performed every 125 hours or quarterly,
whichever comes first.
Required maintenance procedures and additional
engine information is available in the Deutz 1011F
Operation Manual (Deutz part number 0297 9683).
Deutz 1011F Operation Manual
Genie part number
3 - 12
A-11
Drain the Fuel Filter/ Water
Separator - Deutz Models
Engine specifications require that this procedure
be performed every 200 hours or quarterly,
whichever comes first.
Proper maintenance of the fuel filter/water
separator is essential for good engine
performance. Failure to perform this procedure can
lead to poor engine performance and component
damage.
52883
Note: Perform this procedure with the engine off.
1 Release the latches on the engine tray and fully
slide the engine tray out.
2 Insert a 6 inch / 15 cm screwdriver or rod into
the engine tray lock hole located near the
engine tray roller wheels to prevent the engine
tray from moving.
GS-3390 • GS-4390 • GS-5390
Explosion and fire hazard. Engine
fuels are combustible. Perform this
procedure in an open, well-
ventilated area away from heaters,
sparks, flames and lighted
tobacco. Always have an
approved fire extinguisher within
easy reach.
Part No. 72863
July 2007
REV E