HONDA
CLUTCH/OIL
PUMP
CX65OC
OI
k PUMP INSPECTION
Measure the p u m p tip clearance.
SERVICE LIMIT:
0.10
m m
(0.004 in)
Measure the p u m p body clearance.
SERVICE LIMIT:
0.3% m m
(0.014
in)
Measure the p u m p end clearance with a straight
edge and feeler gauge.
SERVICE LIMIT:
0.30 mm
(9.004 in)
Date of
Issue:
December,
1982
O
HONDA MOTOR
CO.,
LTD.