Table 87. Switch statistics (continued)
Field
Broadcast Packets Received The total number of packets received that were directed to the broadcast
Receive Packets Discarded
Octets Transmitted
Packets Transmitted Without
Errors
Unicast Packets Transmitted
Multicast Packets
Transmitted
Broadcast Packets
Transmitted
Transmit Packets Discarded
Most Address Entries Ever
Used
Address Entries in Use
Maximum VLAN Entries
Most VLAN Entries Ever
Used
Static VLAN Entries
VLAN Deletes
Time Since Counters Last
Cleared
Description
address. This does not include multicast packets.
The number of inbound packets that were chosen to be discarded, even though
no errors were detected, in order to prevent their being delivered to a
higher-layer protocol. A possible reason for discarding a packet could be to free
up buffer space.
The total number of octets transmitted out of the interface, including framing
characters.
The total number of packets transmitted out of the interface.
The total number of packets that higher-level protocols requested be transmitted
to a subnetwork-unicast address, including those that were discarded or not
sent.
The total number of packets that higher-level protocols requested be transmitted
to a multicast address, including those that were discarded or not sent.
The total number of packets that higher-level protocols requested be transmitted
to the broadcast address, including those that were discarded or not sent.
The number of outbound packets that were chosen to be discarded, even
though no errors were detected, in order to prevent their being delivered to a
higher-layer protocol. A possible reason for discarding a packet could be to free
up buffer space.
The highest number of Forwarding Database Address Table entries that were
learned by this switch since the most recent reboot.
The number of learned and static entries in the Forwarding Database Address
Table for this switch.
The maximum number of VLANs allowed on this switch.
The largest number of VLANs that were active on this switch since the last
reboot.
The number of active VLAN entries on this switch that were created statically.
The number of VLANs on this switch that were created and then deleted since
the last reboot.
The elapsed time, in days, hours, minutes, and seconds, since the statistics for
this switch were last cleared.