Hardware Description and Basic Operations
Item Indicator
1
LED 1
(green)
2
LED 2
(orange)
Table 17: 2.5'' Hard Drive Disk Indicators
I
Turning On and Shutting Down the System
Turning on the System
To turn on the ETERNUS CS800 S5, proceed as follows:
Entry model only:
1. Switch on the ETERNUS CS800 system by pressing the power buttons located on the
front of the system.
2. If storage module is installed, it is switched on automatically.
3. Wait 15 minutes for the system to boot before continuing with the procedure.
U41840-J-Z125-7-76
Description
HDD BUSY
Lights up: HDD in active phase
●
Does not light: HDD inactive (drive inactive)
●
HDD FAULT
Does not light: no HDD error
●
Lights up: HDD Faulty or Rebuild Stopped (drive defective/needs
●
replacing, a rebuild process was stopped or the HDD module is not
correctly inserted)
Slow flashing: HDD Rebuild (the data is being restored after
●
changing a drive)
Fast flashing: HDD Identify
●
Four fast blinks/pause: HDD Predicted Fault
●
Two fast flashes/pause: HDD Hot Spare (Hot spare drive active.
●
The corresponding drive has failed).
If a drive fails, you will be notified by an admin alert in the remote management
pages (see
"Admin Alerts" on page
Turning On and Shutting Down the System
419).
75