Installing The Rack; Rack Requirements - Fujitsu ETERNUS CS800 S5 User Manual

File
Table of Contents

Advertisement

Installing the Rack

I

Rack Requirements

Table 18
nents.
Height
Width (side to side)
Depth (front to back)
Weight (stand alone) 25 kg
Ventilation Clearance At least 200 mm on the front and rear
Table 18: Rack Requirements - for Entry
Height
Width (side to side)
Depth (front to back)
Weight (stand alone) 60 kg
Ventilation Clearance At least 200 mm on the front and rear
Table 19: Rack Requirements - for Scale
The rack systems from Fujitsu (PRIMECENTER Rack) support the installation of
ETERNUS CS800 S5 components. Installation in most current rack systems from other
manufacturers is also supported.
To ensure proper ventilation, any unused areas in the rack must be sealed using dummy
covers. Ventilation takes place from the front to the back and may not be obstructed!
The power is supplied via the multiple socket outlets fitted in the rack.
U41840-J-Z125-7-76
It is recommended to install the ETERNUS CS800 S5 system in a controlled or
restricted area to prevent access by untrained personnel. In addition, it is
recommended that system installation is performed only by qualified IT personnel.
and
Table 19
contain the rack requirements for the ETERNUS CS800 S5 compo-
ETERNUS CS800 S5 - Entry
2 HU, i.e. 8.9 cm,
48.26 cm
77 cm
ETERNUS CS800 S5 - Scale
4 HU, i.e. 17.8 cm
48.26 cm
77 cm
With JX40 storage modules
4 HU, i.e. 17.8 cm
48.26 cm
77 cm
60 kg
With DX80 S2 expansion modules
Up to 22 HU, i.e. 97.8 cm (9 expansions)
48.26 cm
77 cm
Up to 375 kg