Advanced timings, clamp delay - clamp width

About the advanced settings
Clamp delay
Clamp width
Sync
pulse
Clamp
pulse
Image 9-55
How to change the clamp delay - clamp width
1. Press Menu to activate the menus and select Image → Timings → Advanced settings.
Image 9-56
Main menu, Image
Image 9-58
Timings, advanced settings
2. Press ENTER to select.
R5905158 HDF SERIES 08/12/2016
The time between the trailing edge of the sync pulse and the leading edge of the clamp pulse, in pixels.
Can be any value between 0 and 255.
The width of the clamp pulse can be any value between 0 and 255.
Clamp
Clamp
delay
width
Image 9-57
Image, timings