Provisioning The System Timing - Lucent Technologies LambdaUnite Installation Manual

Multiservice
Hide thumbs Also See for LambdaUnite:
Table of Contents

Advertisement

Provisioning the System Timing

....................................................................................................................................................................................................................................
Overview
Before you begin
Procedure
....................................................................................................................................................................................................................................
5 - 3 4
This section provides a procedure for configuring the system timimg.
Prior to performing this task, you must be logged into the WaveStar
CIT and the respective network element. Furthermore, you must have
completed the task "Configuring the Data Communication Network
(DCN)" (5-30).
Required privilege code
You must have at least a privilege code of P3 to configure the system
timing.
Required equipment
The following equipment is required to perform this task:
WaveStar CIT.
Complete the following steps to configure the system timing:
............................................................................................................................................................
Configuration → Timing/Sync
Select
1
WaveStar CIT.
Result:
The window
............................................................................................................................................................
Select the
System Timing Parameters
2
............................................................................................................................................................
Select the
3
System Timing
............................................................................................................................................................
Select the wait-to-restore time in the group box
4
Click on the respective radio button. The values can be:
Zero
(initial value)
(
20 SEC
SONET
1 Minutes
...
Infinite
(
SONET
The wait-to-restore time is the wait which is made before every single
switching from one timing reference to another.
Lucent Technologies
in the
Synchronisation Characteristics
tab.
mode only)
60 Minutes
(selectable via a spin box)
mode only)
Commissioning
System View
of the
appears.
tab.
Wait To Restore.
Issue a, January 2002
®
365-374-059

Advertisement

Table of Contents
loading