LC Attenuator Selection

....................................................................................................................................................................................................................................
Ordering
Selection procedure
....................................................................................................................................................................................................................................
5 - 4 2
See Appendix B, "LC Attenuators" (B-12).
This section covers the selection of LC attenuators to be used on
the input to the long reach 2.5G/10G based on the received
optical power. It is recommended that the LC attenuator be
placed on the INPUT port since this is the furthest physical point
on the fibre line from the OUTPUT port and takes all connector
losses into account. Perform the steps as described below to
choose and install the appropriate LC attenuator for all port units:
............................................................................................................................................................
At the input of the receiver measure the received optical power from
1
the far-end transmitter. Be sure to set the optical power meter for the
wavelength of the light to be measured (i.e. 1310 nm or 1550 nm).
..........................................................................................................................................................
Check that the measured value is within the range shown below "LC
2
attenuator value range" (5-43)).
IF...
the measured value is
within the range,
the measured value is not
within the range,
............................................................................................................................................................
3
Remove the 0-dB LC attenuator in the faceplate IN port of the optical
circuit pack.
............................................................................................................................................................
Install the chosen LC attenuator.
4
............................................................................................................................................................
Measure the received optical power again.
5
Result:
The measured value must be within the valid range.
E
S
N D
O F
T E P S
............................................................................................................................................................
Lucent Technologies
THEN...
END OF STEPS
choose the appropriate LC attenuator
value.
Commissioning
365-374-059
Issue a, January 2002