Network Commissioning

....................................................................................................................................................................................................................................
Overview
Assumptions
Related information
Procedure
....................................................................................................................................................................................................................................
365-374-059
Issue a, January 2002
This chapter describes how to establish a network with optical fibre
connections. It provides procedures for directly connecting the
LambdaUnite
MSS NEs and should be used for high-level network
connection.
Be sure all listed assumptions described below are fulfilled before
establishing the network:
Each NE is provisioned as described in that chapter.
The person setting up the network should be familiar with the
SDH or SONET functionality.
In this chapter all procedures are described for a protected ring
topology. In the "LambdaUnite MultiService Switch (MSS)
Application, Planning and Ordering Guide" other possible topologies
are also described.
DANGER
Never look into the end of an exposed fiber or into an open
optical connector as long as the optical source is switched
on. This applies particularly to the connections of the optical
plug-in units.
CAUTION
Use a static ground wrist strap whenever handling circuit
packs or working on a WaveStar® CIT, to prevent
electrostatic discharge damage to sensitive components.
CAUTION
To avoid cable break ensure that the bending radius of
optical fibre cables is not less than 30 mm.
Lucent Technologies
Commissioning
5 - 3 9