NE Synchronisation Failure

....................................................................................................................................................................................................................................
Overview
Procedure
....................................................................................................................................................................................................................................
365-374-059
Issue a, January 2002
The procedure described below should be performed if no valid
timing reference signal is received at the respective external
synchronization input (see Chapter 6, section "NE Synchronisation
Test" (6-10)).
Follow the steps below in the case of an NE synchronization
failure:
............................................................................................................................................................
Check for correct cabling and change as necessary.
1
IF ...
the NE does not
synchronize to the external
clock source,
the NE synchronizes to the
external clock source,
..........................................................................................................................................................
Check for correct input impedance (75 Ω, 100/110 Ω, 120 Ω) and
2
change as necessary.
IF ...
the NE does not
synchronize to the external
clock source,
the NE synchronizes to the
external clock source,
..........................................................................................................................................................
Check for an external fault: input/output reversed or exchange supply
3
defect.
IF ...
the NE does not
synchronize to the external
clock source,
Lucent Technologies
Installation Troubleshooting
THEN ...
proceed to step 2.
END OF STEPS
THEN ...
proceed to step 3.
END OF STEPS
THEN ...
proceed to step 4.