Coax 1.6/5.6 Connectors

....................................................................................................................................................................................................................................
Description
Büschel (Isolectra)
....................................................................................................................................................................................................................................
365-374-059
Issue a, January 2002
The connectors are
IMS — type 3320.52.1420.0D5 (45°)
IMS — type 2360.52.1310.0D5 (Straight)
Büschel (Isolectra) — type: 005 12550 320008 (45°)
Important! Make use of the correct tools to ensure a proper
connection
............................................................................................................................................................
Strip the cable according to the dimension indicated in the next figure
1
and tin the centre conductor.
............................................................................................................................................................
Slide the cable outer ferrule and if applicable the bend prevention tube
2
over the stripped cable.
............................................................................................................................................................
Push the centre conductor and the dielectric into the connector house
3
till the dielectric stops. Make sure the braid of the cable is around the
inner ferrule of connector and butted against the connector house
............................................................................................................................................................
4
Solder the center conductor to the center contact.
............................................................................................................................................................
Crimp the outer ferrule, when it is butted against the connector house
5
with Hexagon Die 4.6 (Isolectra) — 24025001000555 by using the
Crimptool (Isolectra) — Z586.
............................................................................................................................................................
Screw the cover of the connector house into the connector and slide
6
the bend prevention tube over the crimped piece.