NE Software Installation
....................................................................................................................................................................................................................................
Overview
Before you begin
Safety precaution
....................................................................................................................................................................................................................................
365-374-059
Issue a, January 2002
The software is initially delivered to the customer on a CD-ROM
(Comcode 109088708). The software generic has to be copied from
the CD-ROM to the WaveStar
™
CompactFlash
card via WaveStar CIT. Afterwards, the
CompactFlash card is inserted into the NE.
Prior to performing this task, you must
1.
have 120 MB of free hard-disk drive space.
2.
have a valid login on both the WaveStar CIT and the NE.
3.
acquire the CD-ROM that contains the generic/version of the NE
software (Comcode 109088708).
Required privilege code
You must have at least a privilege code of S4.
Required equipment
The following equipment is required to perform this task:
•
Empty 256 MB CompactFlash card (as delivered from
manufacturer)
•
CD-ROM that contains the generic/version of the NE software
•
PC with CompactFlash or PCMCIA slot. For the second case an
adapter is required.
Please observe the following safety precaution:
CAUTION
Electrostatic discharge damage to sensitive
components
Handling circuit packs or working on a WaveStar CIT can
cause electrostatic discharge damage to sensitive
components.
Use a static ground wrist strap whenever handling
circuit packs or working on a WaveStar CIT, to prevent
electrostatic discharge damage to sensitive components.
Lucent Technologies
®
CIT PC and then to the empty
Commissioning
5 - 1 1