Lucent Technologies LambdaUnite Installation Manual page 295

Multiservice
Hide thumbs Also See for LambdaUnite:
Table of Contents

Advertisement

Coax 1.6/5.6 Connectors
....................................................................................................................................................................................................................................
365-374-059
Issue a, January 2002
2
Important! Make use of the correct tools to ensure a proper
IMS
connection
............................................................................................................................................................
Strip the cable according to the dimensions indicated in the next
1
figure and tin the centre conductor.
Important! The stripping lengths are connector type dependent!
............................................................................................................................................................
Pull the crimp outer ferrule over the stripped cable.
2
............................................................................................................................................................
Pull back the braid of the cable
3
............................................................................................................................................................
Push the centre conductor and the dielectric into the connector house
4
till the dielectric stops.
............................................................................................................................................................
Solder the inner conductor to the center contact of the connector
5
house
............................................................................................................................................................
Press the cover into the connector body after soldering.
6
............................................................................................................................................................
Roll at first the braid of the cable over the termination part (inner
7
ferrule) of the connector and pull the crimp outer ferrule over that
braid.
............................................................................................................................................................
Crimp the outer ferrule with Hexagon Die 4,6 — AGK 3068 by using
8
Crimptool — AGK 2365.
E
S
N D
O F
T E P S
............................................................................................................................................................
Lucent Technologies
Hexagon Die 4.6 (Isolectra) —
24025001000555
Assembly Instructions
A - 1 5

Advertisement

Table of Contents
loading