Changing the NE Name (TID)
....................................................................................................................................................................................................................................
5 - 2 2
............................................................................................................................................................
Place the cursor in the
4
new TID observing the following configuration rules:
Each NE name must be unique within the network.
The following characters are allowed in an NE name:
-
Upper-case letters ("A" .. "Z"),
-
Lower-case letters ("a" .. "z"),
-
Special characters("-", "+", "_", ".", "/"),
-
Digits ("0" .. "9").
An NE name must not end and begin with an special character.
Each NE name must be maximally 20 characters in length.
The NE name may contain segments separated by hyphens ("-")
or slashes ("/"), but each segment must begin with a letter.
Please note that NE names are case-insensitive.
..........................................................................................................................................................
Make sure that the new TID is correct.
5
IF ...
the new TID is correct,
the new TID is not correct,
............................................................................................................................................................
Place the cursor in the
6
new TID again.
Important! Take a note of the TID you are going to assign to the NE!
............................................................................................................................................................
Click
to assign the new TID and to dismiss the window.
7
OK
............................................................................................................................................................
From the
System View
8
Maintenance Condition...
............................................................................................................................................................
Confirm the resulting system message by clicking
9
Lucent Technologies
New TID/NE Name
text box and key in the
THEN ...
continue with Step 6.
correct the entry in the
text box
Name
and continue with Step 6.
Confirm TID/NE Name
main menu, select
Fault
Exit Maintenance Condition...
Commissioning
New TID/NE
text box and key in the
Enter/Exit
.
.
OK
365-374-059
Issue a, January 2002