Lucent Technologies LambdaUnite Installation Manual page 244

Multiservice
Hide thumbs Also See for LambdaUnite:
Table of Contents

Advertisement

Network Commissioning
....................................................................................................................................................................................................................................
5 - 4 0
Perform the following procedure to establish a protected ring
connection:
............................................................................................................................................................
At the first node, clean and connect the fibre to the OUT port of one
1
optical circuit pack (OP10G or OP2G5).
Reference:
Chapter 7, section "Fibre Cleaning" (7-12)
............................................................................................................................................................
Move to the next adjacent node in the east.
2
............................................................................................................................................................
Follow the LC attenuator selection procedure to determine the correct
3
attenuation value for the IN port of the respective optical circuit pack.
Reference:
Section "LC Attenuator Selection" (5-42)
............................................................................................................................................................
Clean and connect the fibre to this IN port.
4
Reference:
Chapter 7, section "Fibre Cleaning" (7-12)
............................................................................................................................................................
Repeat steps 1-4 until you have gone all the way around the ring.
5
............................................................................................................................................................
Repeat steps 1-5 with other optical circuit packs (OP10G or OP2G5)
6
used for protection.
............................................................................................................................................................
Setup far-end communications.
7
Reference:
Section "Configuring the Data Communication Network (DCN)"
(5-30)
............................................................................................................................................................
Setup cross-connections.
8
Lucent Technologies
Commissioning
365-374-059
Issue a, January 2002