Rack Adapter-Kit

....................................................................................................................................................................................................................................
Before you begin
Installation Procedure
....................................................................................................................................................................................................................................
3 - 3 6
If the existing rack(s) already have side-cover plates, remove these
cover plates from the sides of the existing rack(s) to which another
rack(s) will be connected. See "Side-Cover Plates" (3-34) for
instructions on how to re-install side-cover plates.
............................................................................................................................................................
1
Extension side of the
existing rack is
At the front to the left
At the front to the right
............................................................................................................................................................
Remove the Assy, Cage Nut — DC1002834 on the opposite side to
2
the demounted rack adapter-kit (see Step 1) (two at the top and the
two at the bottom).
............................................................................................................................................................
Place the center style (item 4) of the extension rack next to the
3
existing rack.
............................................................................................................................................................
Put the Bushing for Adapter Kit — CC848316279 (Item 1) in the
4
center style and fix in place using CH SCR, STL ST-70, M4x25 —
CC847117900 (Item 2) and Washer STL, ST-70-140HV, 4.3x12 —
CC847174950 (Item 3) at each nut retainer-position.
............................................................................................................................................................
Tighten the CH SCR, STL ST-70, M4x25 — CC847117900 (Item 2)
5
to tie the rack frame together.
E
S
N D
O F
T E P S
............................................................................................................................................................
Lucent Technologies
Then
Demount the rack adapter-kit on the
extension rack.
Demount the rack adapter-kit on the
existing rack.
Equipment Installation
365-374-059
Issue a, January 2002