D-Sub Metallic Hoods

....................................................................................................................................................................................................................................
Description

Assembly Instructions

....................................................................................................................................................................................................................................
A - 2
The Amphenol metal hoods series for D-Sub connectors offers
protection from magnetic and radio interferencies to cable assemblies.
Easily assembled these hoods are suitable for all industrial and
telecom applications.
............................................................................................................................................................
Important! Be aware to protect the braid by stripping.
Strip the cable according the following dimensions.
1
Result:
Cable stripping dimensions:
Connector type
9 pole
15 pole
25 pole
37 pole
............................................................................................................................................................
Prepare the braid as shown in the figure.
2
............................................................................................................................................................
Solder the wires to the pin contact.
3
............................................................................................................................................................
Put the ferrules around the braid on the cable.
4
Important! Shape the strands of braid into two pigtails and bend
these back over the ferrule in a shape of 180 degrees.
............................................................................................................................................................
Insert the cable with the ferrule in the D-Sub connector.
5
............................................................................................................................................................
Close the connector by tighting the screws.
6
E
S
N D
O F
T E P S
............................................................................................................................................................
Lucent Technologies
A
30mm [1.181"]
45mm [1.772"]
Assembly Instructions
B
20mm [.787"]
20mm [.787"]