Alarm Reporting Test
....................................................................................................................................................................................................................................
365-374-059
Issue a, January 2002
Created alarm
Fan Voltage
Feed A Failure
............................................................................................................................................................
Check whether alarms are reported to the WaveStar CIT (via
3
NE Alarm List...
correct behaviour of the LEDs on the User Panel and on the circuit
pack, which generates the produced failure.
............................................................................................................................................................
Clear alarms created at step 2.
4
............................................................................................................................................................
Check the WaveStar CIT alarm list for correct clearing of the reported
5
alarm. To make sure that the "NE Alarm List" reflects the current
alarm status, click the
............................................................................................................................................................
Repeat step 2 to 5 for all alarm levels.
6
E
S
N D
O F
T E P S
.........................................................................................................................................................................................................................................................
Lucent Technologies
Alarm level
Prompt/Major
or
Reports
NE Alarm List...
button.
Refresh
Test Procedures
Example for creation of
the alarm
1. Reprovision the ASAP
level for the "Fan Voltage
Feed A Failure" alarm from
"Deferred/Minor" to
"Prompt/Major".
2. Disconnect the fan power
cable from the
Power Input A
connector of the Fan Unit
and verify the receipt of a
"Prompt/Major" alarm.
3. Change the ASAP back to
"Deferred/Minor".
Fault
). Check also the
6 - 9