Intelligent Terminal Functions
NOTE:. Mark "" in A line of [ Run Mode Edit] shows the accessible parameters when b031 is not set "10",
high level access.
NOTE:. Mark "" in B line of [ Run Mode Edit] shows the accessible parameters when b031 is set "10",
high level access
Func.
Name
Code
Input [1] function

Input [2] function

Input [3] function

[GS1 assignable]
Input [4] function

[GS2 assignable]
Input [5] function

[PTC assignable]
Input [6] function

Input [7] function

Input [1] active state

Input [2] active state

Input [3] active state

Input [4] active state

Input [5] active state

Input [6] active state

Input [7] active state

Output [11] function

[EDM assignable]
Output [12] function

Alarm relay function

[EO] terminal selection

(Pulse/PWM output)
"C" Function
Description
Select input terminal [1] function, 68
options (see next section)
Select input terminal [2] function, 68
options (see next section)
Select input terminal [3] function, 68
options (see next section)
Select input terminal [4] function, 68
options (see next section)
Select input terminal [5] function, 68
options (see next section)
Select input terminal [6] function, 68
options (see next section)
Select input terminal [7] function, 68
options (see next section)
Select logic conversion, two option codes:
normally open [NO]
normally closed [NC]
48 programmable functions available for
logic (discrete) outputs
(see next section)
48 programmable functions available for
logic (discrete) outputs
(see next section)
13 programmable functions:
Output frequency (PWM)
Output current (PWM)
Output torque (PWM)
Output frequency (Pulse train)
Output voltage (PWM)
Input power (PWM)
Electronic thermal load ratio (PWM)
LAD frequency (PWM)
Output current (Pulse train)
Heat sink temperature (PWM)
General output (PWM)
Pulse train input monitor
Option(PWM)
Ver.263
Run
Mode
Defaults
Edit
A
B
Initial data
Units
00
[FW]
01
[RV]
12
[EXT]
18
[RS]
02
[CF1]
03
[CF1]
06
[JG]
00
00
00
00
00
00
00
00
[RUN]
01
[FA1]
05
[AL]
07
[LAD]