Hitachi WJ200-001S Instruction Manual page 638

Wj200 series single/three-phase inputs 200v/400v class
Hide thumbs Also See for WJ200-001S:
Table of Contents

Advertisement

Func.
Func.
Func.
Func.
N N N N ame
ame
ame
ame
Code
Code
Code
Code
b b b b 0 0 0 0 1 1 1 1 5 5 5 5
Free setting
electronic
thermal ~freq.1
b b b b 0 0 0 0 1 1 1 1 6 6 6 6
Free setting
electronic
thermal
~current1
b b b b 0 0 0 0 1 1 1 1 7 7 7 7
Free setting
electronic
thermal ~freq.2
b b b b 0 0 0 0 1 1 1 1 8 8 8 8
Free setting
electronic
thermal
~current2
b b b b 0 0 0 0 1 1 1 1 9 9 9 9
Free setting
electronic
thermal ~freq.3
b b b b 0 0 0 0 2 2 2 2 0 0 0 0
Free setting
electronic
thermal
~current3
b b b b 0 0 0 0 2 2 2 2 1 1 1 1
Overload
restriction
operation mode
b b b b 22
22
221 1 1 1
22
Overload
restriction
operation mode,
2
nd
motor
b b b b 0 0 0 0 22
22
22
22
Overload
restriction level
b b b b 222
222
222
222
Overload
restriction level,
2
nd
motor
b b b b 0 0 0 0 23
23
23
23
Deceleration rate
at overload
restriction
b b b b 223
223
223
223
Deceleration rate
at overload
restriction, 2
nd
motor
b b b b 0 0 0 0 24
24
24
24
Overload
restriction
operation mode 2
b b b b 0 0 0 0 25
25
25
25
Overload
restriction level 2
b b b b 0 0 0 0 2 2 2 2 6 6 6 6
Deceleration rate
2 at overload
restriction
OC suppression
b b b b 0 0 0 0 2 2 2 2 7 7 7 7
selection
b b b b 0 0 0 0 2 2 2 2 8 8 8 8
Current level of
active freq.
matching
" " " " b b b b " " " " Function
Function
Function
Function
D D D D escription
Range is 0 to 400(580)
*1
Hz
Range is 0 to inverter rated current Amps
Range is 0 to 400(580)
*1
Hz
Range is 0 to inverter rated current Amps
Range is 0 to 400(580)
*1
Hz
Range is 0 to inverter rated current Amps
Select the operation mode during overload conditions, four
options, option codes:
00
00 ... Disabled
00
00
0 0 0 0 1 1 1 1 ... Enabled for acceleration and constant speed
0 0 0 0 2 2 2 2 ... Enabled for constant speed only
0 0 0 0 3 3 3 3 ... Enabled for acceleration and constant speed, increase speed
at regen.
Sets the level of overload restriction, between 20% and 200% of
the rated current of the inverter, setting resolution is 1% of
rated current
Sets the deceleration rate when inverter detects overload, range
is 0.1 to 3000.0, resolution 0.1
Select the operation mode during overload conditions, four
options, option codes:
00 ... Disabled
00
00
00
0 0 0 0 1 1 1 1 ... Enabled for acceleration and constant speed
0 0 0 0 2 2 2 2 ... Enabled for constant speed only
0 0 0 0 3 3 3 3 ... Enabled for acceleration and constant speed, increase speed
at regen.
Sets the level of overload restriction, between 20% and 200% of
the rated current of the inverter, setting resolution is 1% of
rated current
Sets the deceleration rate when inverter detects overload, range
is 0.1 to 3000.0, resolution 0.1
Two option codes:
00
00
00
00 ... Disabled
0 0 0 0 1 1 1 1 ... Enabled without voltage reduction
0 0 0 0 2 2 2 2 ...Enable with voltage reduction
Sets the current level of active freq. matching restart, range is
0.1*inverter rated current to 2.0*inverter rated current,
resolution 0.1
escription
escription
escription
Ver.3− − − − 129
D D D D efaults
efaults
efaults
efaults
A A A A
B B B B
Initial data
Initial data
Initial data
Initial data
Units
Units
Units
Units
0.
Hz
0.00
Amps
0.
Hz
0.00
Amps
0.
Hz
0.00
Amps
01
01
Rated
current
Amps
x 1.5
Rated
current
Amps
x 1.5
1.0
s
1.0
s
01
Rated
current
%
x 1.5
1.0
s
00
Rated
A
current

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents