Hitachi WJ200-001S Instruction Manual page 582

Wj200 series single/three-phase inputs 200v/400v class
Hide thumbs Also See for WJ200-001S:
Table of Contents

Advertisement

Response:
No
Field Name
1
Slave address
2
Function code
3
Byte number n
4
Register Data 1 (high byte)
5
Register Data 1 (low byte)
6
Register Data 2 (high byte)
7
Register Data 2 (low byte)
8
CRC-16 (high byte)
9
CRC-16 (low byte)
Notice the data from fourth to seventh. The Read data (Register Data 1, 2) are subject to Endian function.
(As for the data arrangements of Special Endian, please refer to "[2] How data are arranged by each
endian.")
As you have seen in these examples, Endian function is applied not only to the data in Query but also to
the data in Response. Therefore, aside from when necessary, Response examples will be left out henceforth.
Example
(Hex)
01
17
04
FB
Subject to Endian function :
DE
Read Data : 0 001FBDEh
00
01
69
F9
Ver.3− − − − 73