Hitachi WJ200-001S Instruction Manual page 182

Wj200 series single/three-phase inputs 200v/400v class
Hide thumbs Also See for WJ200-001S:
Table of Contents

Advertisement

Func.
Name
Code
PID FBV output

low limit
Over-torque/under-torque

selection
Over/under-torque level

(Forward powering mode)
Over/under-torque level

(Reverse regen. mode)
Over/under-torque level

(Reverse powering mode)
Over/under-torque level

(Forward regen. mode)
Signal output mode of

Over/under-torque
Electronic thermal

warning level
Zero speed detection level

Heat sink overheat

warning
Overload warning level 2

"C" Function
Description
When the PV goes below this
value, the PID loop turns ON the
PID second stage output, range is
0.0 to 100%
Two option codes:
Over-torque
Under-torque
Set range is 0 to 200%
Set range is 0 to 200%
Set range is 0 to 200%
Set range is 0 to 200%
Two option codes:
During accel., decel. and
constant speed
During constant speed only
Set range is 0 to 100%
Setting 0 means disabled.
Set range is 0.0 to 100.0Hz
Set range is 0 to 110 C
Sets the overload warning signal
level between 0% and 200% (from
0 to two time the rated current of
the inverter)
Defaults
Run
Mode
Initial data
Units
Edit
0.0
00
100.
100.
100.
100.
01
90
0.00
100.
Rated current
x 1.15
397
%
%
%
%
%
%
Hz
C
A