Example 4-3:
Query (Special Endian):
No
Field Name
1
Slave address
2
Function code
3
Start address (high byte)
4
Start address (low byte)
5
Number of holding registers
(high byte)
6
Number of holding registers
(low byte)
7
Byte number
8
Change data 1 (high byte)
9
Change data 1 (low byte)
10
Change data 2 (high byte)
11
Change data 2 (low byte)
12
Change data 3 (high byte)
13
Change data 3 (low byte)
14
CRC-16 (high byte)
15
CRC-16 (low byte)
Notice the data from eighth to thirteenth.
Write data (Change data) are subject to the Endian function.
(As for the data arrangements of Special Endian, please refer to "[2] How data are arranged by each
endian.")
Note) When several parameters are involved, the order of parameter does not change.
The Endian function is applied to data in each parameter
Example
(Hex)
01
10
Register address value = Register
11
Number - 1
04
00
03
06
93
F003 Write data:
E0
000493E0h
00
04
F004 Write data
00
01h
01
EB
DD
Ver.3− − − − 81
The order of
parameters is not
affected by the
Endian setting.