Hitachi WJ200-001S Instruction Manual page 197

Wj200 series single/three-phase inputs 200v/400v class
Hide thumbs Also See for WJ200-001S:
Table of Contents

Advertisement

3112
Encoder (Pulse Train Input) Related Settings
You can achieve speed control or simple positioning control by using pulse train input.
Following table shows the related parameters of those function. Please refer to chapter
4 for the detailed description.
Func.
Code
[EA] terminal selection

Pulse train input mode

selection for feedback
Encoder pulse setting

Simple positioning

selection
Creep Speed

Over-speed error

detection level
Speed deviation error

detection level
Speed control Related Settings
Set "" in  and "" in , then output frequency is controlled by single phase
pulse train input to EA terminal.
"P" Function
Name
Three option codes:
...Speed reference (incl. PID)
...For control with encoder
feedback
...Extended terminal for EzSQ
Four option codes:
...Single-phase pulse [EA]
...2-phase pulse (90 difference)
1 ([EA] and [EB])
...2-phase pulse (90 difference)
2 ([EA] and [EB])
...Single-phase pulse [EA] and
direction signal [EB]
Sets the pulse number (ppr) of the
encoder, set range is 32~1024
pulses
Two option codes:
...simple positioning
deactivated
...simple positioning activated
Set range is start frequency ()
~10.00 Hz
Set range is 0~150%
Set range is 0~120 Hz
Description
Defaults
Run
Mode
Initial data
Units
Edit
00
00
512.
00
5.00
115.0
10.00
Hz
%
Hz

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents