Inverter Mode - Hitachi WJ200-001S Instruction Manual

Wj200 series single/three-phase inputs 200v/400v class
Hide thumbs Also See for WJ200-001S:
Table of Contents

Advertisement

Ver.216
Data Read/Write selection
Setting b166 to "01", you can inhibit both Read, Write function by WOP. This function is different from
"software lock function".
NOTE:. Mark "" in A line of [ Run Mode Edit] shows the accessible parameters when b031 is not set "10",
high level access.
NOTE:. Mark "" in B line of [ Run Mode Edit] shows the accessible parameters when b031 is set "10",
high level access.
Func.
Code
Data Read/Write selection

Inverter mode selection
Current mode of the inverter is displayed in d060.
When initializing or clearing trip history under PM operation mode, please set b084,b085 and b094, which is
the same as a normal procedure of initialization, and execute initialization by setting the initialization trigger
(b180) to 01. b171 setting is not needed.
•When changing the operation mode
It changes to the PM mode by setting the initialization trigger (b180) to 01 after setting the inverter mode
selection (b171) to 03, and initialization is executed.
Oppositely, it changes to the IM mode by setting the initialization trigger (b180) to 01 after setting the inverter
mode selection (b171) to 01, and initialization is executed.
■When changing inverter mode, observe the following precautions.
① The Factory default is IM mode.
② When inverter mode changing, b084 setting is not needed.
③ When PM mode, "Dual Rating Selection" is only "CT mode".
④ When 01 is set on the initialization trigger (b180), and SET key is pressed, initialization starts immediately
and there is not any way to restore the previous parameter setting.
⑤ All data will be initialized independent of b094.
⑥ The settings of "P100" to "P131", running-time data, and power-on time data cannot be cleared.
⑦ When display is restricted by the function code display restriction function (b037) or software is locked by
the software lock function (b031), you cannot initialize because the function codes of initialization are
no-display. If you forget password that restrict setting (b031) and (b037), you cannot cancel it. (So you
cannot initialize when software lock is active, you note that the setting password. (See section 7.6.11 the
password function.))
"b" Function
Name
Read/Write enable
both Read, Write disable
from PM mode to IM, same parameters will be used.
Description
Run
Mode
Defaults
Edit
A
B
Initial data
Units
00
-
 

Advertisement

Table of Contents

Troubleshooting