Parameter group B
Register
Function name
No.
Restart mode on power failure /
1301h
under-voltage trip
Allowable under-voltage power
1302h
failure time
Retry wait time before motor
1303h
restart
Instantaneous power
1304h
failure/under-voltage trip alarm
enable
Number of restarts on power
1305h
failure/under-voltage trip events
1306h
(Reserved)
1307h
Restart frequency threshold
1308h
Restart mode on over voltage /
1309h
over current
130Ah
(Reserved)
Number of retry on over voltage /
130Bh
over current
Retry wait time on over voltage /
130Ch
over current
130Dh
Level of electronic thermal
130Eh
Electronic thermal characteristic
130Fh
(Reserved)
Free setting, electronic thermal
1310h
frequency (1)
Free setting, electronic thermal
1311h
current (1)
Free setting, electronic thermal
1312h
frequency (2)
Free setting, electronic thermal
1313h
current (2)
Free setting, electronic thermal
1314h
frequency (3)
Free setting, electronic thermal
1315h
current (3)
Overload restriction operation
1316h
mode
1317h
Overload restriction level
Deceleration rate at overload
1318h
restriction
Overload restriction operation
1319h
mode (2)
131Ah
Overload restriction level 2
Deceleration rate at overload
131Bh
restriction (2)
Over current suppression
131Ch
*1
enable
Current level of active freq.
131Dh
matching
Deceleration rate of active freq.
131Eh
matching
*1
: Range modified from version 3.0
Function
R/W
Monitoring and setting items
code
0 (tripping), 1 (starting with 0 Hz), 2 (starting
with matching frequency), 3 (tripping after
b001
R/W
deceleration and stopping with matching
frequency), 4 (restarting with active matching
frequency)
b002
R/W 3 to 250
b003
R/W 3 to 1000
0 (disabling), 1 (enabling), 2 (disabling during
b004
R/W
stopping and decelerating to stop)
b005
R/W 0 (16 times), 1 (unlimited)
-
-
-
b007 (high)
R/W
0 to 40000
b007 (low)
R/W
0 (tripping), 1 (starting with 0 Hz), 2 (starting
with matching frequency), 3 (tripping after
b008
R/W
deceleration and stopping with matching
frequency), 4 (restarting with active matching
frequency)
-
-
-
b010
R/W 1 to 3
b011
R/W 3 to 1000
b012
R/W 200 to 1000
0 (reduced-torque characteristic), 1
b013
R/W
(constant-torque characteristic), 2 (free setting)
-
-
Inaccessible
b015
R/W 0 to 400
b016
R/W 0 to Rated current
b017
R/W 0 to 400
b018
R/W 0 to Rated current
b019
R/W 0 to 400
b020
R/W 0 to Rated current
0 (disabling), 1 (enabling during acceleration
and constant-speed operation), 2 (enabling
b021
R/W
during constant-speed operation), 3 (enabling
during acceleration and constant-speed
operation [speed increase at regeneration])
b022
R/W 200 to 2000
b023
R/W 1 to 30000
0 (disabling), 1 (enabling during acceleration
and constant-speed operation), 2 (enabling
b024
R/W
during constant-speed operation), 3 (enabling
during acceleration and constant-speed
operation [speed increase at regeneration])
b025
R/W 200 to 2000
b026
R/W 1 to 30000
0 (disabling),
b027
R/W
1(Enabled without voltage reduction),
2(Enable with voltage reduction)
b028
R/W 100 to 2000
b029
R/W 1 to 30000
Ver.3− − − − 99
Data resolution
-
0.1 [s]
0.1 [s]
-
-
-
0.01 [Hz]
-
-
1 [s]
0.1 [s]
0.1 [%]
-
-
1 [Hz]
0.1 [A]
1 [Hz]
0.1 [A]
1 [Hz]
0.1 [A]
-
0.1 [%]
0.1 [
s
]
-
0.1 [%]
0.1 [
s
]
-
0.1 [%]
s
0.1 [
]

Advertisement