Hitachi WJ200-001S Instruction Manual page 461

Wj200 series single/three-phase inputs 200v/400v class
Hide thumbs Also See for WJ200-001S:
Table of Contents

Advertisement

Ver.232
Register
Function name
No.
1345h to
(Reserved)
1348h
Operation level at O
1349h
disconnection
Operation level at OI
134Ah
disconnection
134Bh to
(reserved)
134Dh
134Eh
Ambient temperature
134Fh to
(reserved)
1350
Cumulative input power data
1351h
clearance
1352h
Watt-hour display gain
1353h to
(Reserved)
1354h
1355h
Start frequency
1356h
Carrier frequency
Initialization mode (parameters
1357h
or trip history)
1358h
Country code for initialization
Frequency scaling conversion
1359h
factor
135Ah
STOP key enable
135Bh
Restart mode after FRS
Automatic
135Ch
reduction
135Dh
Dynamic braking usage ratio
135Eh
Stop mode selection
135Fh
Cooling fan control
1360h
Clear elapsed time of cooling fan
Initialization target data
1361h
1362h
Dynamic braking control
1363h
Dynamic braking activation level
1364h
BRD resistor value
1365h to
(Reserved)
1366h
1367h
Free-setting V/f frequency (1)
1368h
Free-setting V/f voltage (1)
1369h
Free-setting V/f frequency (2)
136Ah
Free-setting V/f voltage (2)
136Bh
Free-setting V/f frequency (3)
136Ch
Free-setting V/f voltage (3)
136Dh
Free-setting V/f frequency (4)
136Eh
Free-setting V/f voltage (4)
136Fh
Free-setting V/f frequency (5)
1370h
Free-setting V/f voltage (5)
1371h
Free-setting V/f frequency (6)
1372h
Free-setting V/f voltage (6)
1373h
Free-setting V/f frequency (7)
1374h
Free-setting V/f voltage (7)
Function
code
-
b070
b071
-
b075
-
b078
b079
-
b082
b083
b084
b085
b086
b087
b088
carrier
frequency
b089
b090
b091
b092
b093
b094
b095
b096
b097
-
b100
b101
b102
b103
b104
b105
b106
b107
b108
b109
b110
b111
b112
b113
R/W
Monitoring and setting items
-
-
R/W
0. to 100. (%) or "no" (ignore)
R/W
0. to 100. (%) or "no" (ignore)
-
-
R/W -10 to 50
-
-
R/W Clearance by setting "1"
R/W 1 to 1000
-
-
R/W 10 to 999
R/W 20 to 150
0,1 (clearing the trip history), 2 (initializing the
data), 3 (clearing the trip history and initializing the
R/W
data), 4 (clearing the trip history and initializing the
data and EzSQ program)
R/W 0 (area A), 1 (area B)
R/W 1 to 9999
R/W 0 (enabling), 1 (disabling), 2 (disabling only stop)
0 (starting with 0 Hz), 1 (starting with matching
R/W
frequency), 2 (starting with active matching
frequency)
0(disabling)/1(enabling( output current controlled))/
2(enabling( fin temperature controlled))
R/W
R/W 0 to 1000
R/W 0 (deceleration until stop), 1 (free-run stop)
0 (always operating the fan), 1 (operating the fan
R/W
only during inverter operation [including 5 minutes
after power-on and power-off]) ,2
R/W 0(count)/1(clear)
R/W 0 to 3
0 (disabling), 1 (enabling [disabling while the motor
R/W
is stopped]), 2 (enabling [enabling also while the
motor is stopped])
R/W 330 to 380, 660 to 760
R/W
Min.Resistance to 6000
-
-
R/W 0. to "free-setting V/f frequency (2)"
R/W 0. to 8000
R/W 0. to "free-setting V/f frequency (3)"
R/W 0. to 8000
R/W 0. to "free-setting V/f frequency (4)"
R/W 0. to 8000
R/W 0. to "free-setting V/f frequency (5)"
R/W 0. to 8000
R/W 0. to "free-setting V/f frequency (6)"
R/W 0. to 8000
R/W 0. to "free-setting V/f frequency (7)"
R/W 0. to 8000
R/W 0. to 400.
R/W 0. to 8000
Data resolution
1 [%]
1 [%]
-
1 [°c]
-
-
1
-
0.01 [Hz]
0.1 [kHz]
-
-
0.01
-
-
-
0.1 [%]
-
-
-
-
1. [V]
0.1[Ω]
-
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents