Hitachi WJ200-001S Instruction Manual page 655

Wj200 series single/three-phase inputs 200v/400v class
Hide thumbs Also See for WJ200-001S:
Table of Contents

Advertisement

Ver.3− − − − 146
O O O O ption
ption
T T T T erminal
erminal
ption
ption
erminal
erminal
C C C C ode
ode
ode
ode
S S S S ymbol
ymbol
ymbol
ymbol
24
24
FA4
24
24
FA5
25
25
25
25
2 2 2 2 6 6 6 6
OL2
2 2 2 2 7 7 7 7
ODc
2 2 2 2 8 8 8 8
OIDc
3 3 3 3 1 1 1 1
FBV
NDc
32
32
32
32
33
33
LOG1
33
33
34
34
34
34
LOG2
LOG3
35
35
35
35
3 3 3 3 9 9 9 9
WAC
WAF
4 4 4 4 0 0 0 0
4 4 4 4 1 1 1 1
FR
42
42
42
42
OHF
LOC
43
43
43
43
44
44
MO1
44
44
45
45
MO2
45
45
O O O O utput Function Summary Table
utput Function Summary Table
utput Function Summary Table
utput Function Summary Table
F F F F unction Name
unction Name
unction Name
unction Name
Frequency Arrival
ON
Type 4–Over frequency
OFF
Frequency Arrival
ON
Type 5–Set frequency
OFF
Overload Advance
ON
Notice Signal 2
OFF
Analog Voltage Input
ON
Disconnect Detection
OFF
Analog Current input
ON
Disconnect Detection
OFF
PID Second Stage
ON
Output
OFF
Network Disconnect
ON
Detection
OFF
Logic Output Function
ON
1
OFF
Logic Output Function
ON
2
OFF
Logic Output Function
ON
3
OFF
Capacitor Life Warning
ON
Signal
OFF
Cooling Fan Warning
ON
Signal
OFF
Starting Contact
ON
Signal
OFF
Heat Sink Overheat
ON
Warning
OFF
Low load detection
ON
OFF
General Output 1
ON
OFF
General Output 2
ON
OFF
D D D D escription
escription
escription
escription
When output to motor is at or above the set
freq., even if in accel (C C C C 0 0 0 0 45
45
45) or decel (C C C C 0 0 0 0 4 4 4 4 6 6 6 6 )
45
ramps
When output to motor is OFF, or at a level below
the set frequency
When output to motor is at the set frequency,
during accel (C C C C 0 0 0 0 45
45
45
45) and decel (C C C C 0 0 0 0 4 4 4 4 6 6 6 6 ).
When output to motor is OFF, or is not at a level
of the set frequency
When output current is more than the set
threshold (C C C C 111
111) for the overload signal
111
111
When output current is less than the set
threshold for the deviation signal
When the [O] input value < b b b b 0 0 0 0 7 7 7 7 0 0 0 0 setting (signal
loss detected)
When no signal loss is detected
When the [OI] input value < b b b b 0 0 0 0 7 7 7 7 1 1 1 1 setting (signal
loss detected)
When no signal loss is detected
Transitions to ON when the inverter is in RUN
Mode and the PID Process Variable (PV) is less
than the Feedback Low Limit (C C C C 0 0 0 0 53
Transitions to OFF when the PID Process
Variable (PV) exceeds the PID High Limit
(C C C C 0 0 0 0 52
52
52
52), and transitions to OFF when the
inverter goes from Run Mode to Stop Mode
When the communications watchdog timer
(period specified by C C C C 0 0 0 0 77
77
77) has time out
77
When the communications watchdog timer is
satisfied by regular communications activity
When the Boolean operation specified by C C C C 1 1 1 1 43
has a logical "1" result
When the Boolean operation specified by C C C C 1 1 1 1 43
has a logical "0" result
When the Boolean operation specified by C C C C 1 1 1 1 4 4 4 4 6 6 6 6
has a logical "1" result
When the Boolean operation specified by C C C C 1 1 1 1 4 4 4 4 6 6 6 6
has a logical "0" result
When the Boolean operation specified by C C C C 1 1 1 1 4 4 4 4 9 9 9 9
has a logical "1" result
When the Boolean operation specified by C C C C 1 1 1 1 4 4 4 4 9 9 9 9
has a logical "0" result
Lifetime of internal capacitor has expired.
Lifetime of internal capacitor has not expired.
Lifetime of cooling fan has expired.
Lifetime of cooling fan has not expired.
Either FW or RV command is given to the
inverter
No FW or RV command is given to the inverter,
or both are given to the inverter
Temperature of the heat sink exceeds a specified
value (C C C C 0 0 0 0 6 6 6 6 4 4 4 4 )
Temperature of the heat sink does not exceed a
specified value (C C C C 0 0 0 0 6 6 6 6 4 4 4 4 )
Motor current is less than the specified value
(C C C C 0 0 0 0 3 3 3 3 9 9 9 9 )
Motor current is not less than the specified
value (C C C C 0 0 0 0 3 3 3 3 9 9 9 9 )
General output 1 is ON
General output 1 is OFF
General output 2 is ON
General output 2 is OFF
53)
53
53
43
43
43
43
43
43

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents