Hitachi WJ200-001S Instruction Manual page 204

Wj200 series single/three-phase inputs 200v/400v class
Hide thumbs Also See for WJ200-001S:
Table of Contents

Advertisement

Multistage position switching function (CP1/CP2/CP3)
When functions " (CP1)" to " (CP3)" are assigned to input terminal [1] to [7] ( to
), you can select multistage positions 0 to 7. Preset position data 0 to 7 in  to
. If no assignment is set in terminals, position command will be position-0 ().
Code








(Note 1) If =, set the number of pulse for one rotation in .
To avoid misinput due to time lag of each input, you can adjust the determination time
in (). The input status is taken the preset time () after the last change of input
status. (Note that a long determination time deteriorates the input response.)
Determination time
Position
command
CP1
CP2
CP3
Item
Multistage position 0
Multistage position 1
Multistage position 2
Multistage position 3
Multistage position 4
Multistage position 5
Multistage position 6
Multistage position 7
Position setting
Multistage position 0 ()
Multistage position 1 ()
Multistage position 2 ()
Multistage position 3 ()
Multistage position 4 ()
Multistage position 5 ()
Multistage position 6 ()
Multistage position 7 ()
()=
7
3
Determination time
() specified
1
ON
Determination time ()
Data or data range
P073 to P072
(Displayed higher
4-digits only)
CP3
CP2
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1
5
4
ON
ON
3119
Description
(Note 1)
CP1
0
1
0
1
0
1
0
1

Advertisement

Table of Contents

Troubleshooting

loading