Hitachi WJ200-001S Instruction Manual page 645

Wj200 series single/three-phase inputs 200v/400v class
Hide thumbs Also See for WJ200-001S:
Table of Contents

Advertisement

Ver.3− − − − 136
Func.
Func.
Func.
Func.
Code
Code
Code
Code
C C C C 0 0 0 0 2 2 2 2 8 8 8 8
[AM] terminal selection
(Analog voltage output
0...10V)
C C C C 0 0 0 0 3 3 3 3 0 0 0 0
Digital current monitor
reference value
C C C C 0 0 0 0 3 3 3 3 1 1 1 1
Output [11] active state
C C C C 0 0 0 0 32
32
32
32
Output [12] active state
Alarm relay active state
C C C C 0 0 0 0 3 3 3 3 6 6 6 6
C C C C 0 0 0 0 3 3 3 3 8 8 8 8
Output mode of low
current detection
C C C C 0 0 0 0 3 3 3 3 9 9 9 9
Low current detection
level
Output mode of overload
C C C C 0 0 0 0 4 4 4 4 0 0 0 0
warning
C C C C 0 0 0 0 4 4 4 4 1 1 1 1
Overload warning level
C C C C 24
24
241 1 1 1
24
Overload warning level,
2
nd
motor
C C C C 0 0 0 0 42
42
42
42
Frequency arrival setting
for acceleration
Frequency arrival setting
C C C C 0 0 0 0 43
43
43
43
for deceleration
C C C C 0 0 0 0 44
44
PID deviation level
44
44
Frequency arrival setting
C C C C 0 0 0 0 45
45
45
45
2 for acceleration
C C C C 0 0 0 0 4 4 4 4 6 6 6 6
Frequency arrival setting
2 for deceleration
C C C C 0 0 0 0 4 4 4 4 7 7 7 7
Pulse train input/output
scale conversion
C C C C 0 0 0 0 52
52
PID FBV output
52
52
high limit
C C C C 0 0 0 0 53
53
53
53
PID FBV output
low limit
C C C C 0 0 0 0 54
54
Over-torque/under-torque
54
54
selection
Over/under-torque level
C C C C 0 0 0 0 55
55
55
55
(Forward powering mode)
C C C C 0 0 0 0 5 5 5 5 6 6 6 6
Over/under-torque level
(Reverse regen. mode)
C C C C 0 0 0 0 5 5 5 5 7 7 7 7
Over/under-torque level
(Reverse powering mode)
" " " " C C C C " " " " Function
Function
Function
Function
N N N N ame
ame
ame
ame
11 programmable functions:
00 ... Output frequency
00
00
00
0 0 0 0 1 1 1 1 ... Output current
0 0 0 0 2 2 2 2 ... Output torque
0 0 0 0 4 4 4 4 ... Output voltage
0 0 0 0 5 5 5 5 ... Input power
0 0 0 0 6 6 6 6 ... Electronic thermal load ratio
0 0 0 0 7 7 7 7 ... LAD frequency
1 1 1 1 0 0 0 0 ... Heat sink temperature
11 ... Output torque (with code)
11
11 11
1 1 1 1 3 3 3 3 ... General output
1 1 1 1 6 6 6 6 ... Option
Current with digital current monitor output at 1,440Hz
Range is 20%~200% of rated current
Select logic conversion, two option codes:
00 ... normally open [NO]
00
00
00
0 0 0 0 1 1 1 1 ... normally closed [NC]
Two option codes:
00 ... During acceleration, deceleration and constant speed
00
00
00
0 0 0 0 1 1 1 1 ... During constant speed only
Set the level of low load detection, range is 0.0 to 2.0 *
inverter rated current
Two option codes:
00
00 ... During accel., decel. and constant speed
00
00
0 0 0 0 1 1 1 1 ... During constant speed only
Sets the overload warning signal level between 0% and
200% (from 0 to two time the rated current of the inverter)
Sets the frequency arrival setting threshold for the output
frequency during acceleration,
range is 0.0 to 400.0(580.0)
Sets the frequency arrival setting threshold for the output
frequency during deceleration,
range is 0.0 to 400.0(580.0)
Sets the allowable PID loop error magnitude (absolute
value), SP-PV, range is 0.0 to 100%
Set range is 0.0 to 400.0(580.0)
Set range is 0.0 to 400.0(580.0)
If EO terminal is configured as pulse train input
(C027=15), scale conversion is set in C047.
Pulse-out = Pulse-in × (C047)
Set range is 0.01 to 99.99
When the PV exceeds this value, the PID loop turns OFF
the PID second stage output, range is 0.0 to 100%
When the PV goes below this value, the PID loop turns ON
the PID second stage output, range is 0.0 to 100%
Two option codes:
00
00 ... Over-torque
00
00
0 0 0 0 1 1 1 1 ... Under-torque
Set range is 0. to 200.%
Set range is 0. to 200.%
Set range is 0. to 200.%
D D D D escription
escription
escription
escription
*1
Hz
*1
Hz
*1
Hz
*1
Hz
D D D D efaults
efaults
efaults
efaults
A A A A
B B B B
In In In Initial
itial
itial
itial
Units
Units
Units
Units
data
data
data
data
07
[LAD]
Rated
A
current
00
00
-
01
01
Rated
A
current
01
Rated
current
A
x 1.15
Rated
current
A
x 1.15
0.00
Hz
0.00
Hz
3.0
%
0.00
Hz
0.00
Hz
1.00
-
100.0
%
0.0
%
00
-
100.
%
100.
%
100.
%

Advertisement