Main Profile Parameters
NOTE:. Mark " " in A line of [ Run Mode Edit] shows the accessible parameters when
b031 is not set "10", high level access.
NOTE:. Mark " " in B line of [ Run Mode Edit] shows the accessible parameters when
b031 is not set "10", high level access.
* Please change from"
B037
(Function code display restriction), in case some parameters cannot be displayed.
Func.
Name
Code
Output frequency setting
F001
Acceleration time (1)
F002
Acceleration time (1),
F202
2
motor
nd
Deceleration time (1)
F003
Deceleration time (1),
F203
2
motor
nd
Keypad RUN key routing
F004
04
(Basic display)" to "
"F" Function
Standard default target
frequency that determines
constant motor speed, range is
0.0 / start frequency to
maximum frequency (A004)
Standard default acceleration,
range is 0.01 to 3600 sec.
Standard default deceleration,
range is 0.01 to 3600 sec.
Two options; select codes:
00 ...Forward
01 ...Reverse
00
(Full display)" in parameter
Description
Run
Mode
Defaults
Edit
A
B
Initial data
Units
0.0
Hz
10.0
sec.
10.0
sec.
10.0
sec.
10.0
sec.
00
C− − − − 3