Func.
Code
Software lock mode

selection
NOTE: To disable parameter editing when using  lock modes  and , assign the
[SFT] function to one of the intelligent input terminals.
See "Software Lock" in chapter 4
Motor Cable Length Parameter
To achieve higher motor control performance, the WJ200 inverter has the Motor Cable
Length Parameter setting . Normally there is no need to adjust this parameter,
however in case of long motor cable and/or shielded cable, where there is a
comparatively higher earth capacitance, set this parameter higher to achieve better
motor control performance.
Note that the parameter is indicative and no formula to calculate the suitable value.
Normally, longer the motor cable, bigger the set value. Please adjust depending on your
system.
For 11 and 15kW inverter, it is not needed to set b033.
Func.
Code
Motor cable length

parameter
"b" Function
Name
Prevents parameter changes, in five
options, option codes:
all parameters except  are
locked when [SFT] terminal is ON
all parameters except  and
output frequency  are locked
when [SFT] terminal is ON
all parameters except  are
locked
all parameters except  and
output frequency  are locked
High level access including 
See appendix C for the accessible
parameters in this mode.
"b" Function
Name
Set range is 5 to 20.
Description
Description
Run
Defaults
Mode
Initial data
Units
Edit
01
Defaults
Run
Mode
Initial data
Units
Edit
10.