Ver.3− − − − 106
Register
Function name
No.
1466h
EzCOM start adr. of master
1467h
EzCOM end adr. of master
1468h
EzCOM starting trigger
Up/Down memory mode
1469h
selection
146Ah
Reset mode selection
146Bh
Restart mode after reset
UP/DWN clear mode
146Ch
146Dh
FM gain adjustment
146Eh
AM gain adjustment
(Reserved)
146Fh
1471h
AM bias adjustment
1472h
(Reserved)
1473h
Overload warning level 2
1474h to
(Reserved)
1485h
1486h
Output [11] on-delay time
1487h
Output [11] off-delay time
1488h
Output [12] on-delay time
1489h
Output [12] off-delay time
148Ah to
(Reserved)
148F
1490h
Output RY on-delay time
1491h
Output RY off-delay time
1492h
Logic output 1 operand A
1493h
Logic output 1 operand B
1494h
Logical output 1 operator
1495h
Logic output 2 operand A
1496h
Logic output 2 operand B
1497h
Logical output 2 operator
1498h
Logic output 3 operand A
1499h
Logic output 3 operand B
149Ah
Logical output 3 operator
149Bh to
(Reserved)
14A3h
14A4h
Input [1] response time
14A5h
Input [2] response time
14A6h
Input [3] response time
14A7h
Input [4] response time
14A8h
Input [5] response time
14A9h
Input [6] response time
14AAh
Input [7] response time
14ABh to
(Reserved)
14ACh
14ADh
Multistage speed/position determination time
14AEh to
unused
14CBh
14CCh
IRDY action selection
14CDh to
unused
1500h
: Available from version 3.0
*2
Function code
R/W
C098
R/W 1~8
C099
R/W 1~8
C100
R/W 00(Input terminal), 01(Always)
C101
R/W
C102
R/W
C103
R/W
C104
R/W
C105
R/W 50 to 200
C106
R/W 50 to 200
-
-
C109
R/W 0 to 100
-
-
C111
R/W 0 to 2000
-
-
C130
R/W 0 to 1000
C131
R/W 0 to 1000
C132
R/W 0 to 1000
C133
R/W 0 to 1000
-
-
C140
R/W 0 to 1000
C141
R/W 0 to 1000
C142
R/W
C143
R/W
C144
R/W 0 (AND), 1 (OR), 2 (XOR)
C145
R/W
C146
R/W
C147
R/W 0 (AND), 1 (OR), 2 (XOR)
C148
R/W
C149
R/W
C150
R/W 0 (AND), 1 (OR), 2 (XOR)
-
-
C160
R/W 0 to 200
C161
R/W 0 to 200
C162
R/W 0 to 200
C163
R/W 0 to 200
C164
R/W 0 to 200
C165
R/W 0 to 200
C166
R/W 0 to 200
-
-
C169
R/W 0 to 200
-
-
*2
C900
R/W 0(Before Ver. 3.0), 1(Ver. 3.0 or after)
-
-
Monitoring and setting items
0 (not storing the frequency data), 1 (storing the
frequency data)
0 (resetting the trip when RS is on), 1 (resetting the trip
when RS is off), 2 (enabling resetting only upon tripping
[resetting when RS is on]), 3(resetting only trip)
0 (starting with 0 Hz), 1 (starting with matching
frequency), 2 (restarting with active matching frequency)
0 (0Hz)/1 (EEPROM data)
Inaccessible
-
-
-
Same as the settings of C021 to C026 (except those of
LOG1 to LOG6, OPO, no)
Same as the settings of C021 to C026 (except those of
LOG1 to LOG6, OPO, no)
Same as the settings of C021 to C026 (except those of
LOG1 to LOG6, OPO, no)
Same as the settings of C021 to C026 (except those of
LOG1 to LOG6, OPO, no)
Same as the settings of C021 to C026 (except those of
LOG1 to LOG6, OPO, no)
Same as the settings of C021 to C026 (except those of
LOG1 to LOG6, OPO, no)
-
-
Inaccessible
Inaccessible
Data
resolution
-
-
-
-
1 [%]
1 [%]
1 [%]
1 [%]
1 [%]
0.1 [%]
-
0.1 [s]
0.1 [s]
0.1 [s]
0.1 [s]
-
0.1 [s]
0.1 [s]
-
-
-
-
-
-
-
-
-
-
-
-
-