Ver.3− − − − 104
Register
Function name
No.
1415h
Output [11] function
1416h
Output [12] function
1421h to
(Reserved)
1423h
141Ah
Alarm relay function
141Bh
[EO] terminal selection
141Ch
[AM] terminal selection
141Dh
(reserved)
Digital current monitor
141Eh
reference value
141Fh
Output [11] active state
1420h
Output [12] active state
1421h to
(Reserved)
1423h
1424h
Alarm relay active state
1425h
(Reserved)
Output mode of low current
1426h
detection
1427h
Low current detection level
1428h
Overload signal output mode
1429h
Overload warning level
Function
R/W
code
0 (RUN: running), 1 (FA1: constant-speed reached), 2 (FA2: set
frequency overreached), 3 (OL: overload notice advance signal
(1)), 4 (OD: output deviation for PID control), 5 (AL: alarm signal),
6 (FA3: set frequency reached), 7 (OTQ: over-torque), 9 (UV:
undervoltage), 10 (TRQ: torque limited), 11 (RNT: operation time
C021
R/W
over), 12 (ONT: plug-in time over), 13 (THM: thermal alarm
signal), 19 (BRK: brake release), 20 (BER: braking error), 21 (ZS:
0 Hz detection signal), 22 (DSE: speed deviation maximum), 23
(POK: positioning completed), 24 (FA4: set frequency
overreached 2), 25 (FA5: set frequency reached 2), 26 (OL2:
overload notice advance signal (2)), 31 (FBV: PID feedback
comparison), 32 (NDc: communication line disconnection), 33
(LOG1: logical operation result 1), 34 (LOG2: logical operation
result 2), 35 (LOG3: logical operation result 3), 39 (WAC:
capacitor life warning), 40 (WAF: cooling-fan), 41 (FR: starting
contact signal), 42 (OHF: heat sink overheat warning), 43 (LOC:
C022
R/W
low-current indication signal), 44 (M01: general-purpose output 1),
45 (M02: general-purpose output 2), 46 (M03: general-purpose
output 3), 50 (IRDY: inverter ready), 51 (FWR: forward rotation),
52 (RVR: reverse rotation), 53 (MJA: major failur)
54 (WCO: window comparator O), 55 (WCO: window comparator
OI), 58(FREF),59(REF),60(SETM),62(EDM),63(OPO:Option)
-
-
C026
R/W
0 (output frequency), 1 (output current), 2 (output torque), 3
(digital output frequency), 4 (output voltage), 5 (input power), 6
C027
R/W
(electronic thermal overload), 7 (LAD frequency), 8 (digital current
monitoring), 10 (heat sink temperature), 12 (general-purpose
output YA0),15 ,16(option)
0 (output frequency), 1 (output current), 2 (output torque), 4
(output voltage), 5 (input power), 6 (electronic thermal overload), 7
C028
R/W
(LAD frequency), 10 (heat sink temperature), 11 (output torque
[signed value]), 13 (general-purpose output YA1),16(option)
-
-
-
C030
R/W 200 to 2000
C031
R/W 0 (NO), 1 (NC)
C032
R/W 0 (NO), 1 (NC)
-
-
-
C036
R/W 0 (NO), 1 (NC)
-
-
-
0 (output during acceleration/deceleration and constant-speed
C038
R/W
operation), 1 (output only during constant-speed operation)
C039
R/W 0 to 2000
00 (output during acceleration/deceleration and constant-speed
C040
R/W
operation), 01 (output only during constant-speed operation)
C041
R/W 0 to 2000
Monitoring and setting items
Data
resolution
-
-
-
-
-
-
-
0.1 [%]
-
-
-
-
-
-
0.1 [%]
-