Series Programmable Controllers
3UC
User's Manual - Hardware Edition
Number and
Content of register
name
N:N Network (setting)
[D]8170
[D]8171
Not used
[D]8172
[D]8173
Station number
[D]8174
Total number of slave stations
[D]8175
Refresh range
D 8176
Station number setting
D 8177
Total slave station number setting
D 8178
Refresh range setting
D 8179
Retry count setting
D 8180
Comms time-out setting
[D]8181
Not used
Index Register Z1 to Z7 and V1 to V7
[D]8182
Value of Z1 register
[D]8183
Value of V1 register
[D]8184
Value of Z2 register
[D]8185
Value of V2 register
[D]8186
Value of Z3 register
[D]8187
Value of V3 register
[D]8188
Value of Z4 register
[D]8189
Value of V4 register
[D]8190
Value of Z5 register
[D]8191
Value of V5 register
[D]8192
Value of Z6 register
[D]8193
Value of V6 register
[D]8194
Value of Z7 register
[D]8195
Value of V7 register
[D]8196
[D]8197
Not used
[D]8198
[D]8199
436
C Operation of Special Devices (M8000 -, D8000 -)
Correspond-
Number and
ing special
name
device
N:N Network (monitoring)
[D]8200
[D]8201
[D]8202
[D]8203
[D]8204
[D]8205
M8038
[D]8206
[D]8207
[D]8208
[D]8209
[D]8210
[D]8211
[D]8212
[D]8213
[D]8214
[D]8215
[D]8216
[D]8217
[D]8218
[D]8219 to [D]8259 Not used
Analog Special Adapter (For details, refer to Appendix C-3.)
D 8260 to D 8269
D 8270 to D 8279
D 8280 to D 8289
D 8290 to D 8299
*1. Supported in Ver. 1.20 or later
*2. The number of connected FX
ADP, FX
3U
counted from the main unit side.
C-2 Special Data Register (D8000 to D8511)
Content of register
Not used
Current link scan time
Maximum link scan time
Number of communication error at
master station
Number of communication error at
slave station No.1
Number of communication error at
slave station No.2
Number of communication error at
slave station No.3
Number of communication error at
slave station No.4
Number of communication error at
slave station No.5
Number of communication error at
slave station No.6
Number of communication error at
slave station No.7
Code of communication error at
master station
Code of communication error at
slave station No.1
Code of communication error at
slave station No.2
Code of communication error at
slave station No.3
Code of communication error at
slave station No.4
Code of communication error at
slave station No.5
Code of communication error at
slave station No.6
Code of communication error at
slave station No.7
*1*2
1st special adapter
*1*2
2nd special adapter
*1*2
3rd special adapter
*1*2
4th special adapter
-4AD-ADP, FX
3U
-4AD-TC-ADP and FX
-4AD-PT-ADP units is
3U
Correspond-
ing special
device
M8183
to
M8191
-4DA-
3U

Advertisement