FX
Series Programmable Controllers
3UC
User's Manual - Hardware Edition
Appendix A-2-6 Cautions on using transparent function by way of USB in GOT1000 Series
When monitoring circuits, device registration, etc. or reading/writing programs in an FX
Developer Ver.8.22Y or later using the transparent function by way of USB in the GOT1000 Series, make
sure to execute the following setting.
If the following setting is not provided, a communication error occurs.
When using transparent function by way
of USB in GOT1000 Series
When using transparent function by way
of RS-232 in GOT1000 Series
When directly connecting GX Developer
to PLC
Setting in GX Developer (Ver. 8.22Y or later)
1
Select [Online] → [Transfer setup...] to open the "Transfer setup" dialog box.
2
Double-click [Serial] in [PC side I/F] to open the "PC side I/F Serial setting"
dialog box.
3
Select "USB (GOT Transparent mode)".
4
Click the [OK] button to finish the setting.
418
GX Developer Ver.8.21X or former
Not supported (not available)
Set "COM port" and "Transmission
speed" on "PC side I/F Serial
setting" dialog box.
Double-click it.
A Version Information and Peripheral Equipment Connect ability
Select "USB (GOT
transparent mode)"
A-2 Programming Tool Applicability
PLC from GX
3UC
GX Developer Ver8.22Y or later
Setting shown below is required.
Select "RS-232C" in setting shown
below, and set "COM port" and
"Transmission speed".