9.18.14 Remote device station input (output) data area
[BFM #144 (90h) to #159 (9Fh) and #208 (D0h) to #223 (DFh)]
This area is used to access the input (output) data in the remote device station indirectly using the FROM and
TO instructions or directly using the buffer memory specification.
Access is enabled to only BFMs for which remote device stations are actually connected.
(The TO instruction is ignored and the FROM instruction returns "0" for a station number to which a remote
I/O station is connected.)
Station No.
Station No.49
Station No.50
Station No.63
Station No.64
318
BFM#
Remote input area Remote output area
144
145
158
159
9 CC-Link/LT Built-in master ability (Only FX3UC-32MT-LT)
208
209
222
223
9.18 Details of buffer memory