Summary Of Functions - Mitsubishi FX3UC SERIES User Manual

Hide thumbs Also See for FX3UC SERIES:
Table of Contents

Advertisement

FX
Series Programmable Controllers
3UC
User's Manual - Hardware Edition
10.2

Summary of Functions

The display module functions are summarized below.
Item
Main unit I/O operation
display
Menu screen functions
Monitor/Test
ErrorCheck
LANGUAGE (selects the
menu display language)
Contrast
ClockMenu
(Time setting)
EntryCode
ClearAllDev
(Device all clear)
PLC Status
ScanTime
Cassette
(Memory cassette transfer)
Non-menu functions
Operation button ON/OFF
information
Hexadecimal current value
display setting
Display screen protect
function
User message display
1) There is no test function for "Input (X)".
2) A sequence program is required to enable a hexadecimal display of the timer (T), counter (C), data
register (file register) (D), extended register (R) [16-bit/32-bit], and extended file register (ER) [16-bit/32-
bit] current values.
320
Displays the ON/OFF status of inputs X000 to X017
and outputs Y000 to Y017 built in the main unit.
*1
Input (X)
, output (Y), auxiliary relay (M), state (S),
timer (T), counter (C), data register (D) [16-bit/32-bit],
Devices
extended register (R), and extended file register (ER)
[16-bit/32-bit] monitor/test function.
User
(User-
Up to 4 data registers (D) [16-bit/32-bit] can be
registered
registered.
device)
Performs error checks and displays the results.
Selects either Japanese or English as the menu
display language.
Adjusts the contrast (-5 to 10); default setting: 0
Setting
Sets the current time.
Display
Displays the current time.
The currently specified entry code can be canceled.
Initializes the Input (X)
state (S), timer (T), counter (C), data register (D) [16-
bit/32-bit], and extended register (R). The file register
(D) is excluded from this function. (Bit devices are
turned OFF, and word device current values are set to
"0".)
Verifies the version information, entry code status,
program memory type status, and battery voltage, etc.
Displays the scan time (max./min./current value)
Allows data transfers (and consistency checks)
between the internal RAM and the memory cassette.
Allows monitoring of operation button ON/OFF status.
Changes the display format of the current values and
setting values for the timer, counter, data register,
extended register, and extended file register to a
hexadecimal display format.
Enables all functions, prohibits change (test) functions,
and protects the Main unit I/O operation display.
The following codes saved at the display device can be
used as display commands:
Alphanumeric: 20H to 7DH ASCII code
Katakana: A1H to DFH ASCII code
Japanese character: Shift JIS Level-1, 2
10 Display Module (Only FX3UC-32MT-LT)
Function
*1
, output (Y), auxiliary relay (M),
→ Refer to Section 10.18 for the setting procedure.
10.2 Summary of Functions
Remarks
Reference
Button
Subsection 10.3.2
operation
Subsection 10.3.3
Button
Section 10.5
operation
Requires
Section 10.6 and
program
Section 10.20
Button
Section 10.7
operation
Button
Section 10.8
operation
Button
Section 10.9
operation
Subsection10.10.1
Button
operation
Subsection10.10.2
Button
Section 10.11
operation
Button
Section 10.12
operation
Button
Section 10.13
operation
Button
Section 10.14
operation
Button
Section 10.15
operation
Requires
program or
Section 10.19
monitor
Requires
Section 10.18
*2
program
Requires
Section 10.17
program
Requires
Section 10.21
program