Source output
Two +V
terminals (connected to each other inside the
PLC) are provided for sink outputs in the FX
transistor output type extension blocks (source type) for the
FX
2NC.
For external wiring, connect two +V
PLC so that the load applied on each +V
becomes smaller.
2. External power supply
For driving the load, use a smoothing power supply of 5 to 30V DC that can output current two or more times
the rated current of the fuse connected to the load circuit.
3. Insulation of circuit
The internal circuit of the PLC and the output transistor are insulated with a photocoupler.
The common blocks are separated from one another.
4. Display of operation
Operation indicator LEDs are built into the main unit and output extension blocks, and turn ON when
photocouplers are actuated. The FX
can be monitored with the display module.
5. Response time
The time from when the PLC drives (or shuts down) the photocoupler until the transistor is turned on (or off) is
shown in the following table.
Classification
Y000 to Y002
(FX
Main units
(FX
Y004 to Y017
For FX
Extension
blocks
For FX
*1.
The transistor OFF time is longer under lighter loads. For example, under a load of 24V DC 40mA, the
response time is approx. 0.3ms. When response performance is required under light loads, provide a
dummy resistor as shown below to increase the load current.
• Sink output type
Fuse
terminals outside the
-32MT-LT does not have operation indicator LEDs, but the operation
3UC
Response
time
5 µs or less
Y003
MT/
0.2 ms or less
3UC-
D, DSS)
Y003
5 µs or less
-32MT-LT)
3UC
0.2 ms or less 24V DC 100mA
Series
2NC
0.2 ms or less
/FX
Series
0N
2N
Dummy
Load
resistance
Y010
COM1
COM1
6 Output Specification and External Wiring
main unit,
3UC
5 to 30V
DC
terminal
Load current
When using an instruction related to pulse
5 to 24V DC 10mA
train output or positioning, make sure to set
or more
the load current to 10 to 100mA (5 to 24V
DC).
*1
24V DC 100mA
When using an instruction related to
5 to 24V DC 10mA
positioning, make sure to set the load
or more
current to 10 to 100mA (5 to 24V DC).
*1
*1
24V DC 100mA
*1
24V DC 200mA
• Source output type
PLC
Load
Fuse
6.2 Transistor Output
Source output type
Load
Y000
Y001
+V0
Fuse
+V0
PLC
PLC
Dummy
resistance
Y010
+V0
+V0