3.11.2 Input/Output terminal block (European type) [FX
WIRING PRECAUTIONS
• Make sure to cut off all phases of the power supply externally before attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
• Make sure to attach the terminal cover, offered as an accessory, before turning on the power or initiating operation
after installation or wiring work.
Failure to do so may cause electric shock.
• Make sure to properly wire to the European terminal board in accordance with the following precautions.
Failure to do so may cause electric shock, a short-circuit, wire breakage, or damage to the product.
- The disposal size of the cable end should follow the dimensions described in this manual.
- Tightening torque should be between 0.22 and 0.25 N
- Twist the end of strand wire and make sure that there are no loose wires.
- Do not solder-plate the electric wire ends.
- Do not connect more than the specified number of wires or electric wires of unspecified size.
- Affix the electric wires so that neither the terminal block nor the connected parts are directly stressed.
1. Connection to terminal block
Terminal block type input/output extension blocks for FX
for FX
/FX
2NC
3UC
2. Electric wires
Compliant electric wires and tightening torque
One electric wire 0.3mm
Two electric
wires
Bar terminal with
insulating sleeve
3. Treatment of electric wire ends
Treat the ends of stranded wires and solid wires without coating or using bar terminals with insulating sleeve.
• Treatment of stranded wires and solid wires without coating
- Twist the ends of stranded wires tightly so that loose wires will not
stick out.
- Do not solder-plate the electric wire ends.
• Treatment using bar terminal with insulating sleeve
It may be difficult to insert the electric wire into the insulating sleeve
depending on the thickness of the electric wire sheath. Select the
electric wire referring to the outline drawing.
Manufacturer
Phoenix Contact
124
have the European type terminal block.
Electric wire size
(stranded wire/solid wire)
2
2
to 0.5mm
(AWG22 to 20)
2
0.3mm
(AWG22)
2
2
0.3 mm
to 0.5 mm
(AWG22 to 20)
(Refer to the following outline
drawing of bar terminal.)
Model names
AI 0.5-8WH
3 Generic Specifications/Installation Work
3.11 Connection to Input/Output Connector
/FX
2NC
m.
and terminal block type special function blocks
2NC
Tightening
torque
• Remove the coating of the stranded wire, twist
the core wires, and connect the wires directly.
• Remove the coating from the solid wire, and
connect the wire directly.
• Bar terminal with insulating sleeve
0.22 to 0.25N•m
(recommended product)
AI 0.5-8WH : Phoenix Contact
• Caulking tool
CRIMPFOX ZA 3 : Phoenix Contact
(CRIMPFOX UD 6 : Phoenix Contact)
Caulking tool
CRIMPFOX ZA 3
(CRIMPFOX UD 6)
extension block]
3UC
End treatment
• Stranded wire/solid wire
9mm
(0.36")
• Bar terminal with insulating sleeve
Insulating sleeve
Contact area
(Crimp area)
8mm
(0.32")
2.6mm
(0.11")
14mm(0.56")

Advertisement