2. Output extension block
Example of program
M8000
SEGL
Example of wiring
1) In the case of sink wiring
Use the sink only input, sink only output type main unit and a transistor output (sink only output) type
output extension block. The wiring example is the [FX
block [FX
2NC
7-segment display to be used for sink wiring
(in the case of transistor output)
PLC
Y
COM1
* Use a 7-segment display with a latch and a built-in BCD decoder.
2) In the case of source wiring
Use the sink/source common input, source only output type main unit and a transistor output (source only
output) type output extension block. The wiring example is the [FX
block [FX
2NC
7-segment display to be used for source wiring
(in the case of transistor output)
PLC
+V0
Y
* Use a 7-segment display with a latch and a built-in BCD decoder.
208
D100 Y020
K1
-16EYT].
FX
-32MT/D
3UC
FX
-32MT-LT
3UC
COM1
7-segment display
+
Signal
Internal
circuit
-
-16EYT-DSS].
FX
-32MT/DSS
3UC
7-segment display
+
Signal
Internal
circuit
-
7.8 Seven Segment with Latch [SEGL (FNC 74)/BCD (FNC 18)]
-32MT/D or FX
3UC
Transistor output (sink)
COM1
Y020
Y021 Y022 Y023 Y024 Y025 Y026 Y027
1
2
3
10
1
2
4
8
Fuse
Transistor output (source)
+V0
+V0
Y020
Y021 Y022 Y023 Y024 Y025 Y026 Y027
1
2
10
3
1
2
4
8
Fuse
7 Examples of Wiring for Various Uses
-32MT-LT] + output extension
3UC
4
8
10
0
10
1
2
1
0
10
10
10
*
-32MT/DSS] + output extension
3UC
FX
2NC
4
8
10
0
10
10
2
10
1
10
0
*
FX
-16EYT
2NC
10
2
10
3
-16EYT-DSS
1
10
2
10
3