Installation Of The High-Voltage Transformer Jig - Toshiba e-STUDIO206L Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

[A] Installation of the high-voltage transformer jig
The high-voltage transformer jig is composed of 2 cables and 1 adapter with a harness.
Attach them to the process unit as shown in the figure.
* Black cable (thick line): Use the screw for the jig. (M3 x 8)
* Red cable (thick line): Use the screw for the process unit.
* Adapter: Use the screw for the process unit.
Notes:
The adjustment may damage the drum. Therefore be sure to replace the drum with the one that
you brought (or the one for measurement) before starting the adjustment.
Harness
Screw
Black cable (thick line)
(1)
Open the automatic duplexing unit.
(2)
Open the front cover and take off the toner
cartridge.
(3)
Loosen 2 screws and pull out the process
unit.
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
SETTING / ADJUSTMENT
Change the drum
Screw
Adapter
Disconnect 1 connector
Fig.6-21
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
6 - 46
Screw
Red cable (thick line)
Process unit
Fig.6-22

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents