6.8
Process Unit Related Section
6.8.1

High-Voltage Transformer Setting

The high-voltage transformers supply high-voltage to the parts related to charging, development,
transfer and Discharging blade.
The high-voltage transformer has the following high-voltage outputs.
Out1
1
Main charger needle electrode cleaner bias (Y)
2
Main charger needle electrode cleaner bias (M)
3
Main charger needle electrode cleaner bias (C)
4
Main charger needle electrode cleaner bias (K)
Out2
1
Main charger grid bias (Y)
2
Main charger grid bias (M)
3
Main charger grid bias (C)
4
Main charger grid bias (K)
Out3
1
Developer bias (Y)
2
Developer bias (M)
3
Developer bias (C)
4
Developer bias (K)
Out4
1
1st transfer roller bias (Y)
2
1st transfer roller bias (M)
3
1st transfer roller bias (C)
4
1st transfer roller bias (K)
Out5
-
2nd transfer roller bias
Notes:
Never move the variable resistance on the board since the output adjustment has been
performed at the shipment for the high-voltage transformer supplied as a service part. Also do
not perform the setting change when the high-voltage power supply is replaced.
6.8.2
Adjustment of the Auto-Toner Sensor
When the developer material is replaced, adjust the auto-toner sensor in the following procedure.
 P. 6-2"6.1.2 Adjustment of the Auto-Toner Sensor"